| Device Tested | Date | Eng/Tested by | Test Freq #1 | Radiated Power | Test Freq #2 | Radiated Power | Test Freq #3 | Radiated Power | Notes |
| (MHz) | (dBW/Hz) | (MHz) | (dBW/Hz) | (MHz) | (dBW/Hz) | ||||
| Allphase CX-EV48 CCTV Camera | 12/22/98 | T.Weadon/CDN | 170 | -117.7 | 320 | -140.1 | 630 | -148.9 | |
| CCTV Camera for GBT | 02/26/98 | T.Weadon/CDN | 96 | 172 | 248 | ||||
| Duracom Switching Power Supply | 07/29/97 | D.Pedtke/CDN | 100 | 150 | 220 | ||||
| Duracom Switching Power Supply | 08/01/97 | D.Pedtke/CDN | 108 | 140 | 196 | ||||
| Duracom Switching Power Supply | 09/09/97 | D.Pedtke/CDN | 134 | 183 | 284 | ||||
| Duracom Switching Power Supply | 10/02/97 | D.Pedtke/CDN | *** | *** | *** | Unit installed in shielded box | |||
| Gateway 2000 NT Server "Halebop" | 03/27/98 | G.Hunt/CDN | 130 | 866 | 1348 | ||||
| Gateway 2000 PC "Spica" | 04/16/97 | RJL/CDN | 100 | 250 | 700 | ||||
| Gateway G6-400 PC w/acces. | 08/25/98 | CDN | 108 | -137.5 | 496 | -136.4 | 992 | -139.4 | |
| HP 53181A Freq. Cntr. | 02/20/97 | S.Heatherly/RDN | Test data incomplete for calculating RFI potential | ||||||
| Melles Griot 56DLD403 Laser Power Supply | 07/20/98 | D.Schiebel/CDN | 47.6 | 95.2 | 149.6 | ||||
| Melles Griot 56DLD403 Laser Power Supply | 08/03/98 | D.Schiebel/CDN | Tests for troubleshooting RFI from shielded power cable. No significant changes noted. | ||||||
| Melles Griot 56DLD403 Laser Power Supply | 09/22/98 | D.Schiebel/CDN | *** | *** | *** | ||||
| Melles Griot 56DLD403 Laser Power Supply | 10/01/98 | D.Schiebel/CDN | 159 | -169.7 | 196.5 | -174.4 | 459.3 | -171.3 | |
| Olympus D-600L Digital Camera | 07/23/98 | R.Lacasse/CDN | 130 | 620 | 936 | ||||
| Pioneer LaserDisc Player | 12/11/97 | R. Fleming/CDN | 172 | 241 | 415 | ||||
| Power Mac PCs & Shield Twstd Pr | 10/01/97 | J.Ford/CDN | 101 | 550 | 832 | ||||
| Sun SPARC Ultra I "Rigel" | 03/24/97 | RDN/RJL | Results were invalid due to RF amp overloading | ||||||
| Sun SPARC Ultra I "Rigel" | 04/23/97 | RJL/CDN | 208 | 500 | 980 | ||||
| Totally Accurate Clock (GPS Rcvr) | 10/03/97 | F.Ghigo/CDN | 100 | 286 | 519 | ||||
| Turbo Vac Pump | 05/08/97 | CDN | 103 | 305 | 440 | ||||
| Vac Ion Pump | 06/12/97 | CDN | Test invalid because dewar was not properly cooled. | ||||||