April 14, 2004 TBASERDN040414 Have test dewar in Eq Rm, with Q-band LNA, mixer, and IF amp. LNA input terminated with rectangular waveguide load at 21K. Connected into OR1, CM1, SF1, and ACS J1. ACS in 1 bank, 2 sampler, 800MHz mode (but no input to sampler 2). LO1 set to 9GHz (fsky=42GHz). 1 : SCAN STARTING AT 53109 12:25:05 1 : SCAN FINISHED AT 53109 12:26:10 T=60s. Started scan sequence. 2 : SCAN STARTING AT 53109 12:27:53 22 : SCAN FINISHED AT 53109 12:53:56 T->361s. 23 : SCAN STARTING AT 53109 12:55:20 24 : SCAN FINISHED AT 53109 13:07:41 25 : SCAN STARTING AT 53109 13:07:50 @ 13:08, applied power to heater on input termination (12V, 100mA). Load=22.0K, LNA=20.8 @ 13:08 Load=33.0K, LNA= 21.1K @13:11 Load=32.8K, LNA=21.0K @ 13:13. 25 : SCAN FINISHED AT 53109 13:13:56 26 : SCAN STARTING AT 53109 13:14:05 26 : SCAN FINISHED AT 53109 13:20:11 27 : SCAN STARTING AT 53109 13:20:20 27 : SCAN FINISHED AT 53109 13:26:26 28 : SCAN STARTING AT 53109 13:26:35 Load=32.9K, LNA=20.8 @ 13:26; Heater -> Off Load=21.8K, LNA=20.1 @ 13:30 28 : SCAN FINISHED AT 53109 13:32:41 29 : SCAN STARTING AT 53109 13:32:50 29 : SCAN FINISHED AT 53109 13:38:56 30 : SCAN STARTING AT 53109 13:39:05 30 : SCAN FINISHED AT 53109 13:45:11 (Scans 31-50 were DCR scans on another problem.) Returned to ACS setup. Changed LO1 frequency to 9.25GHz (fsky=43GHz). Rebalanced ACS. 51 : SCAN STARTING AT 53109 15:21:47 52 : SCAN FINISHED AT 53109 15:34:08 Load=21.4K, LNA=20.2 @ 15:34 53 : SCAN STARTING AT 53109 15:34:17 Load Htr -> On @15:34:30 SF1 TP 1.02 -> 1.29 Load=32.6K, LNA=20.9 @ 15:40 53 : SCAN FINISHED AT 53109 15:40:23 54 : SCAN STARTING AT 53109 15:40:32 55 : SCAN FINISHED AT 53109 15:52:53 Heater -> Off at 15:53:20. 56 : SCAN STARTING AT 53109 15:53:02 56 : SCAN FINISHED AT 53109 15:59:08